ISSN 1016-5169 | E-ISSN 1308-4488
pdf
Percutaneous Balloon Valvuloplasty in Newborn with Critical Pulmonary Stenosis: Report of Two Cases [Turk Kardiyol Dern Ars]
Turk Kardiyol Dern Ars. 1996; 24(2): 126-128

Percutaneous Balloon Valvuloplasty in Newborn with Critical Pulmonary Stenosis: Report of Two Cases

İ. Levent SALTIK1, Gülhis BATMAZ1, Ayşe SARIOĞLU1, Servet ÖZTÜRK1, Sevda ARAT1

Percutaneous balloon angioplasty was performed in two neonates with critical pulmonary stenosis with intact ventricular septum aged 5 and 7 days. Because of technical insufficiency, only coronary angioplasty balloons with maximum diameter of 4 mm were used in each patient. The gradients were only reduced by 30 and 40 mm Hg, respectively; however, elinical cyanosis of the patients ameliorated, prostaglandin infusion could be discontinued and urgent surgery was no longer needed. After 2.5 months, the angioplasty was repeated in one patient. Both patients are still in good elinical condition.



Manuscript Language: Turkish
×
APA
NLM
AMA
MLA
Chicago
Copied!
CITE


Journal Metrics

Journal Citation Indicator: 0.18
CiteScore: 1.1
Source Normalized Impact
per Paper:
0.22
SCImago Journal Rank: 0.348

Quick Search

Copyright © 2024 Archives of the Turkish Society of Cardiology



Kare Publishing is a subsidiary of Kare Media.