ISSN 1016-5169 | E-ISSN 1308-4488
Anomalous origin of one pulmonary artery branch from the ascending aorta: experience of our center [Turk Kardiyol Dern Ars]
Turk Kardiyol Dern Ars. 2010; 38(6): 411-415

Anomalous origin of one pulmonary artery branch from the ascending aorta: experience of our center

Abdullah Erdem1, Numan Ali Aydemir2, Halil Demir1, Cenap Zeybek1, Turkay Sarıtaş1, Celal Akdeniz1, Ali Rıza Karaci2, Ahmet Çelebi1
1Dr. Siyami Ersek Thoracic And Cardiovascular Surgery Center, Department of Pediatric Cardiology, Istanbul, Turkey
2Dr. Siyami Ersek Thoracic And Cardiovascular Surgery Center, Department of Cardiovascular Surgery, Istanbul, Turkey


OBJECTIVES
Anomalous origin of one pulmonary artery branch from the aorta in the presence of separate aortic and pulmonary valves is a rare but important entity necessitating early diagnosis and surgery to prevent irreversible vascular pulmonary disease. We evaluated our experience with seven infants having this anomaly.

STUDY DESIGN
Between December 2003 and 2009, a total of seven infants (2 girls, 5 boys, age range 4 days to 84 days) were diagnosed as having anomalous origin of one pulmonary artery branch from the aorta. Clinical records were reviewed for clinical features, operative procedures, and postoperative follow-up.

RESULTS
Common symptoms were dyspnea, tachypnea, and poor feeding. All the cases were diagnosed by echocardiography. The right pulmonary artery in six cases and the left pulmonary artery in one case originated from the ascending aorta. In addition, three patients had patent ductus arteriosus (PDA), five patients had patent foramen ovale, and one patient had interruption of the aortic arch and aortopulmonary window. All patients underwent surgical re-implantation of the anomalous pulmonary artery branch to the pulmonary trunk. Associated surgical procedures included PDA ligation in three patients, and total repair of interrupted aortic arch and aortopulmonary window in one patient. There were no in-hospital deaths. Two patients had prolonged intubation (10 and 16 days). All patients were discharged in good clinical condition. During a follow-up period ranging from two months to six years, only one patient developed stenosis at the site of anastomosis.

CONCLUSION
Prompt diagnosis at infancy, improved surgical technique, and good patient care decrease mortality and morbidity associated with anomalous origin of the pulmonary artery from the aorta.

Keywords: Echocardiography, heart defects, congenital/surgery; infant, newborn; pulmonary artery/abnormalities/surgery

Corresponding Author: Abdullah Erdem, Türkiye
Manuscript Language: English
×
APA
NLM
AMA
MLA
Chicago
Copied!
CITE


Journal Metrics

Journal Citation Indicator: 0.18
CiteScore: 1.1
Source Normalized Impact
per Paper:
0.22
SCImago Journal Rank: 0.348

Quick Search

Copyright © 2024 Archives of the Turkish Society of Cardiology



Kare Publishing is a subsidiary of Kare Media.