ISSN 1016-5169 | E-ISSN 1308-4488
Long-term outcomes of Absorb bioresorbable vascular scaffold using predilation, sizing, and postdilation protocol in a real-world patient population [Turk Kardiyol Dern Ars]
Turk Kardiyol Dern Ars. 2021; 49(1): 40-50 | DOI: 10.5543/tkda.2020.99249

Long-term outcomes of Absorb bioresorbable vascular scaffold using predilation, sizing, and postdilation protocol in a real-world patient population

Sinem Çakal, Beytullah Çakal, Oğuz Karaca, Bilal Boztosun
Department of Cardiology, İstanbul Medipol University Faculty of Medicine, İstanbul, Turkey


OBJECTIVE
Bioresorbable vascular scaffolds (BVSs) have been a disappointment in the evolution of drug-eluting stents used in percutaneous coronary intervention because an excessive number of thrombotic complications have been reported. The aim of this study was to evaluate long-term clinical outcomes of the Absorb BVS in patients treated using a predilation, proper sizing, and post-dilation implantation technique.


METHODS
The records of 110 patients who had a total of 150 Absorb BVSs implanted were retrospectively analyzed. The rate of major adverse cardiovascular events (MACEs), defined as the composite of cardiac death, target vessel myocardial infarction (MI), and target-lesion revascularization were studied using quantitative coronary angiography.


RESULTS
Of the study population, 80% were male and the mean age was 60±11.3 years. The most common diagnosis was stable angina (84%). The median length of follow-up was 53 months (range: 46–59 months). The rate of predilation and postdilation was 100%, and 95%, respectively. The 4-year rate of MACEs was 20%: cardiac death in 3 patients (2.7%), target vessel MI in 9 (8.2%), and target lesion revascularization in 20 (18.2%). Definite device thrombosis occurred in 6 of 110 patients (5.5%). One case of very late scaffold thrombosis was observed at 47 months. A small BVS diameter (2.5 mm) was found to be the most powerful independent predictor of a MACE (p=0.05).


CONCLUSION
The Absorb BVS was associated with an increased risk of adverse events, including late and very late device thrombosis, despite the use of a good implementation protocol.

Keywords: Absorb bioresorbable vascular scaffold, coronary artery disease; percutaneous coronary intervention.

Corresponding Author: Sinem Çakal, Türkiye
Manuscript Language: English
×
APA
NLM
AMA
MLA
Chicago
Copied!
CITE


Journal Metrics

Journal Citation Indicator: 0.18
CiteScore: 1.1
Source Normalized Impact
per Paper:
0.22
SCImago Journal Rank: 0.348

Quick Search

Copyright © 2024 Archives of the Turkish Society of Cardiology



Kare Publishing is a subsidiary of Kare Media.